Answers are grounded in this paper and cite their sources.
Preclinical study demonstrates complete tumour ablation in rats using contiguous focused ultrasound beams, highlighting the need for full-volume coverage to prevent regrowth.
Discrete implanted liver tumours in the rat have been exposed to arrays of 1.7 MHz ultrasound lesions. Focal peak intensities in the range 1.4-3.5 k Wcm-2 were used for an exposure time of 10 s. It has been demonstrated that where the whole tumour volume was exposed to the focused ultrasound beam, no evidence of tumour growth could be detected histologically. Where the ultrasonic lesion array was not contiguous, regrowth occurred. Preliminary histological studies confirmed this finding.
No takes yet. Share an insight, caveat, or question.
Haar et al. (1991) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: