Answers are grounded in this paper and cite their sources.
Spirometers were designed and used originally for the measurement of metabolic rate or such respiratory constants as vital capacity.Such measurements are made at low rates of respiration (up to about 40 breaths per minute) or with single inspiratory or expiratory efforts.There has been no reason to suspect the accuracy of records made under these conditions.Since Hermannsen (1933) first described the maximum breathing capacity test (M.B.C.) many investigators have used the spirometer to record tidal air at consider- ably higher rates of breathing.During an investigation into the M.B.C. of a series of subjects D' Silva and Mendel (1950) noted that at respiratory rates higher than 55 breaths per minute the oscillatory movements of the water in their spiro- meter were of such violence that very often water was aspirated into the tubes connecting the subject to the instrument, and that aspiration invariably occurred at these high respiratory rates if the tidal air was large.The large movements of the water column which they noted must have been either the cause, or the result, of considerable pressure changes within the spirometer bell, and it seemed that these pressure changes might affect the excursions of the bell and so invalidate the M.B.C. estimations.It was decided therefore to investigate the response of the spirometer at various respiratory rates in order to determine: (a) the magnitude of the errors produced, if any, and (b) whether it would be possible to construct a calibration curve for the instrument so that the errors could be corrected.DESCRIPTION OF THE SPIROMETER This was the same instrument as that used by D'Silva and Mendel in their experiments.It is of the Knipping type (manufactured by C. F. Palmer), and the CO2 absorber and circulating pump had been removed.Details of the moving parts of the instrument, except the pulleys, are given in Table I. METHODFirst the accuracy of the instrument as a volume recorder under static conditions was checked over the full range, from 0 to 6 litres, by introducing known small incre- mental volumes of air and recording the movements of the bell on the special charts provided.Secondly the accuracy as a volume recorder under dynamic conditions was studied by measuring the excursion of the bell produced by pumping a constant volume of air into and out of the spirometer at different repetitive rates.
No takes yet. Share an insight, caveat, or question.
Bernstein et al. (1951) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: