Answers are grounded in this paper and cite their sources.
The mechanism of the breakdown occurring when a dc ramp voltage is applied to low-density polyethylene (LDPE) and silane cross-linked PE at high temperatures is discussed, using experimental results on the Young's modulus Y , high-field conduction and pre-breakdown currents. The electric strength F B of PE was found to be a function of Y , irrespective of cross-linking. It was also found that, over a wide temperature range, a sharp pre-breakdown current increase could not be detected till a time before breakdown of 100 ns, the resolution limit of the measuring system. The results showed that, under the present experimental conditions, thermal breakdown is not applicable to PE over a wide temperature range and that breakdown is initiated by an electronic process which has a very short time lag to breakdown of the order of some tens of ns or less.
No takes yet. Share an insight, caveat, or question.
Hikita et al. (1985) studied this question.