Key result
Reduced heart rate and blood pressure coupling identified via SLDS modeling was associated with severe sepsis in ICU patients.
Why the study?
Does a switching linear dynamical systems (SLDS) machine learning approach applied to nonstationary vital-sign time series accurately capture autonomic regulation changes and identify severe sepsis in adult ICU patients?
Cohort (n=453)
No
Does a switching linear dynamical systems (SLDS) machine learning approach applied to nonstationary vital-sign time series accurately capture autonomic regulation changes and identify severe sepsis in adult ICU patients?
This study demonstrates that a switching linear dynamical systems machine learning framework can noninvasively quantify autonomic baroreflex and cardiorespiratory coupling from noisy, nonstationary vital signs, revealing that blunted HR/BP coupling is independently associated with severe sepsis in ICU patients.
Answers are grounded in this paper and cite their sources.
May support SLDS-based autonomic monitoring for ICU sepsis risk; leaves open prospective validation before clinical adoption.
Physiological variables, such as heart rate (HR), blood pressure (BP) and respiration (RESP), are tightly regulated and coupled under healthy conditions, and a break-down in the coupling has been associated with aging and disease. We present an approach that incorporates physiological modeling within a switching linear dynamical systems (SLDS) framework to assess the various functional components of the autonomic regulation through transfer function analysis of nonstationary multivariate time series of vital signs. We validate our proposed SLDS-based transfer function analysis technique in automatically capturing 1) changes in baroreflex gain due to postural changes in a tilt-table study including ten subjects, and 2) the effect of aging on the autonomic control using HR/RESP recordings from 40 healthy adults. Next, using HR/BP time series of more than 450 adult ICU patients, we show that our technique can be used to reveal coupling changes associated with severe sepsis (AUC = 0.74, sensitivity = 0.74, specificity = 0.60). Our findings indicate that reduced HR/BP coupling is significantly associated with severe sepsis even after adjusting for clinical interventions (P 0.001). These results demonstrate the utility of our approach in phenotyping complex vital-sign dynamics, and in providing mechanistic hypotheses in terms of break-down of autoregulatory systems under healthy and disease conditions.
No takes yet. Share an insight, caveat, or question.
Lehman et al. (2016) conducted a cohort in Severe sepsis in adult ICU patients (n=453). Switching linear dynamical systems (SLDS) transfer function analysis of HR/BP coupling (high-risk dynamic Mode 2) vs. Adult ICU patients without severe sepsis / low-risk dynamic modes was evaluated on Severe sepsis on the first day of ICU admission (OR 1.64, 95% CI 1.28-2.11, p=0.0001). Reduced heart rate and blood pressure coupling identified via SLDS modeling was associated with severe sepsis in ICU patients.