Key result
Male patients had greater maximum right atrial appendage volume and ejection volume compared to female patients.
Why the study?
The study was conducted to assess the volume and function of the right atrial appendage in patients with sinus rhythm using 256-slice spiral CT angiography.
Observational (n=60)
No
Multi-phase 3D CT angiography can effectively evaluate the volume and function of the right atrial appendage, demonstrating that RAA volume changes synchronously with the right atrium and correlates with body weight and body surface area.
Answers are grounded in this paper and cite their sources.
RAA volume reference data from CT in sinus rhythm may inform imaging interpretation; leaves open prognostic or therapeutic relevance.
OBJECTIVE: To assess the volume and function of the right atrial appendage (RAA) in patients with sinus rhythm using 256-slice spiral computed tomography (CT) angiography. METHODS: A total of 60 patients with normal cardiac CT imaging features were enrolled in this retrospective study. The raw imaging data were used to reconstruct 3D images, which were analyzed to measure the volume of the RAA and right atrium (RA) throughout the cardiac cycle, and to obtain the maximum and minimum volume of the RAA and RA (RAAVmax, RAAVmin and RAVmax, RAVmin). Additionally, the RAA ejection volume (RAAEV), RAA ejection fraction (RAAEF), RA ejection volume (RAEV), and ejection fraction (RAEF) were calculated. Independent sample t-tests were used to analyze the data of the RAA and RA between male and female groups. Pearson correlation analysis was used to analyze the correlation between RAA parameters, RA parameters and basic physiological parameters of the human body. RESULTS: The volumes of the RAA and RA constantly changed throughout the cardiac cycle, characterized by similar curves and two emptying phases. During 65–85% of the cardiac cycle, the volume of RAA exhibited a minimal fluctuation, indicating a resting state. Male patients had significantly (P < 0.05) greater values than female in the RAAVmax, RAAEV, RAVmax, and RAVmin(P = 0.003, P = 0.001, P = 0.031 and P = 0.025, respectively). RAAVmax correlated with the patient’s weight, body surface area (BSA), RAVmax, RAVmin and RAAVmin (r = 0.434 P = 0.001, r = 0.363 P = 0.004, r = 0.331 P = 0.010, r = 0.352 P = 0.006 and r = 0.858 P = 1.9485E-18, respectively), but did not significantly correlated with height. RAAVmin positively correlated with the weight, BSA, RAVmax, and RAVmin (r = 0.434 P = 0.011, r = 0.363 P = 0.035, r = 0.331 P = 0.006, and r = 0.352 P = 0.000368, respectively), but did not significantly correlated with height. Additionally, RAAEV correlated with weight, BSA, RAAVmax, and RAAVmin (r = 0.426 P = 0.001, r = 0.356 P = 0.005, r = 0.885, P = 5.9452E-21 and r = 0.521 P = 0.00020, respectively). RAAEF showed a negative correlation with both RAAVmin and RAVmin (r=–0.478 P = 0.000112 and r=–0.289 P = 0.025, respectively). CONCLUSION: CT angiography with multi-phase three-dimensional volume reconstruction is very helpful in evaluating the volume and function of RAA, providing an important guidance for diagnosis and treatment of cardiac diseases.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2025) conducted an observational in Normal sinus rhythm (n=60). Male sex vs. Female sex was evaluated on Maximum right atrial appendage volume (RAAVmax) (p=0.003). Male patients had greater maximum right atrial appendage volume and ejection volume compared to female patients.
Synapse has enriched 10 related papers. Consider them for comparative context: