Key result
Dual source computed tomography yielded slightly larger planimetric mitral valve areas compared to transthoracic echocardiography (1.42 vs 1.35 cm2; P=0.018), with good correlation (r=0.934).
Why the study?
Does dual source computed tomography accurately assess mitral valve area and Wilkins score compared to transthoracic echocardiography in patients with rheumatic mitral stenosis?
Cross-Sectional (n=31)
No
Does dual source computed tomography accurately assess mitral valve area and Wilkins score compared to transthoracic echocardiography in patients with rheumatic mitral stenosis?
Mean Difference: 0.07
Absolute Event Rate: 1.42% vs 1.35%
p-value: p=0.018
DSCT is a reliable alternative to TTE for assessing mitral valve area in patients with rheumatic mitral stenosis, showing excellent correlation.
May support DSCT as alternative for mitral valve area when TTE limited; leaves open prospective outcome validation before practice change.
PURPOSE: There are different clinical cardiac applications of dual source computed tomography (DSCT). Here, we aimed to compare the DSCT with the transthoracic echocardiography (TTE) for evaluating the Wilkins score and planimetric mitral valve area (MVA) of a rheumatic stenotic mitral valve. MATERIALS AND METHODS: We prospectively evaluated mitral valvular structure and function in 31 patients with known mitral stenosis undergoing electrocardiogram-gated, second-generation DSCT, in our heart center for different indications. Mitral valve was evaluated using Wilkins score, and also, the planimetric MVA was assessed. RESULTS: We found a significant difference between MVAs determined by DSCT (average 1.42 ± 0.44 cm2) and MVAs determined by TTE (average 1.35 ± 0.43 cm2 ; difference 0.07 ± 0.16 cm2; P = 0.018). Linear regression analysis revealed a good correlation between the two techniques (r = 0.934; P < 0.0001). The limits of agreement for DSCT and TTE in the Bland-Altman analysis were ±0.31 cm2 . DSCT using TTE as the reference enabled good discrimination between mild and moderate-to-severe stenosis and had an area under the ROC curve of 0.967 (CI 0.912-1.023; P < 0.0001). Wilkins scores obtained by DSCT (7.51 ± 1.17, range 5-10) and TTE (8.16 ± 1.27, range 6-10) had a moderate correlation (r = 0.686; P < 0.0001). CONCLUSION: We found that planimetric MVA measurements assessed by DSCT were closely correlated with MVA calculations by TTE. The moderate correlation was observed for the Wilkins score.
No takes yet. Share an insight, caveat, or question.
Aksu et al. (2015) conducted a cross-sectional in Rheumatic stenotic mitral valve (n=31). Dual source computed tomography (DSCT) vs. Transthoracic echocardiography (TTE) was evaluated on Planimetric mitral valve area (MVA) (MD 0.07, p=0.018). Dual source computed tomography yielded slightly larger planimetric mitral valve areas compared to transthoracic echocardiography (1.42 vs 1.35 cm2; P=0.018), with good correlation (r=0.934).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: