Key result
CMR strongly correlates with 3D TEE for assessing planimetric MVA in rheumatic mitral stenosis.
Why the study?
Does cardiac magnetic resonance (CMR) correlate with three-dimensional transesophageal echocardiography (3D TEE) in assessing planimetric mitral valve area in patients with rheumatic mitral stenosis?
Observational (n=28)
Does cardiac magnetic resonance (CMR) correlate with three-dimensional transesophageal echocardiography (3D TEE) in assessing planimetric mitral valve area in patients with rheumatic mitral stenosis?
Answers are grounded in this paper and cite their sources.
Planimetric CMR is a viable noninvasive alternative to 3D TEE for assessing mitral valve area in rheumatic mitral stenosis.
AIM: Rheumatic heart disease is a common cause of valvular disease, especially in developing countries. Echocardiography is the gold standard investigation modality for cardiac valves. In rheumatic mitral stenosis (MS), three-dimensional transesophageal echocardiography (3D TEE) provides better alignment of the image plane at the mitral tips and more accurate and reproducible planimetric measurement of mitral valve area (MVA). Cardiac magnetic resonance (CMR) is a new method that provides evaluation of cardiac anatomy and function noninvasively. Previous studies showed strong correlation between planimetric MVA measured by two-dimensional transthoracic echocardiography and CMR. We aimed to compare the planimetric MVAs assessed by 3D TEE and CMR in rheumatic MS patients. To best of our knowledge, this is the first study that compares 3D TEE and CMR for the assessment of the planimetric MVA in rheumatic MS. METHODS: We retrospectively evaluated 28 rheumatic MS patients who underwent 3D TEE and ECG-gated CMR. 3D TEE planimetric MVAs were measured manually by multiplanar reconstruction (MPR) method and CMR planimetric MVAs were measured manually on short-axis cine images. Then, 3D TEE and CMR measurements were compared. RESULTS: ) were found to be highly correlated (P < 0.0001, r: 0.744) with Pearson correlation analysis. Bland-Altman analysis showed strong agreement between two techniques. CONCLUSION: For the diagnosis and the follow-up of rheumatic MS, planimetric CMR MVA is an alternative noninvasive method which highly correlates with planimetric 3D TEE MVA.
No takes yet. Share an insight, caveat, or question.
Uygur et al. (2018) conducted an observational in Rheumatic mitral stenosis (n=28). Cardiac magnetic resonance (CMR) vs. Three-dimensional transesophageal echocardiography (3D TEE) was evaluated on Planimetric mitral valve area (MVA) (r=0.744, p=<0.0001). Cardiac magnetic resonance assessment of planimetric mitral valve area was highly correlated with 3D transesophageal echocardiography in patients with rheumatic mitral stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: