Why the study?
Does real-time 3D-TEE provide accurate and reproducible mitral valve area measurements compared to 2D-TTE in patients with mitral stenosis?
Does real-time 3D-TEE provide accurate and reproducible mitral valve area measurements compared to 2D-TTE in patients with mitral stenosis?
3D-TEE provides accurate and reproducible mitral valve area measurements comparable to 2D-TTE planimetry, offering a viable alternative for patients with poor echocardiographic windows.
Answers are grounded in this paper and cite their sources.
3D-TEE may offer an alternative MVA measure in mitral stenosis with poor 2D windows; leaves open need for multi-operator validation before wider adoption.
AIMS: Planimetry measured by two-dimensional transthoracic echocardiography (TTE, MVA2D) is the reference method for the evaluation of the severity of mitral stenosis (MS) but requires experienced operators and good echocardiographic windows. Real-time three-dimensional transoesophageal echocardiography (3D-TEE, MVA3D) may overcome these limitations but its accuracy has never been evaluated. METHODS AND RESULTS: We prospectively enrolled 80 patients (58±15 years, 86% female) referred for MS evaluation who underwent, within 1 week, a clinically indicated TTE and TEE. MVA2D was measured by experienced operators (Level III), MVA3D by one experienced and one non-experienced (Level I) operators blinded of any clinical or TTE information. MVA3D measured by the experienced operator [1.11±0.32 cm2; median, 1.1 cm2; range (0.45-2.20)] did not differ from and correlated well with MVA2D [1.10±0.34 cm2; median, 1.05 cm2; range (0.45-2.30)], P=0.87; r=0.79, P<0.0001; ICC=0.79) and mean difference between methods was small (+0.004±0.21 cm2). MVA3D measured by the non-experienced operator [1.08±0.34 cm2; median 1.02 cm2; range (0.45-2.23)] also did not differ from and correlated well with MVA2D measured by experienced operators (P=0.25; r=0.86, P<0.0001; mean difference -0.02±0.18 cm2; ICC=0.86). Intra and interobserver variability were 0.02±0.25 and 0.01±0.33 cm2. CONCLUSION: 3D-TEE provides accurate and reproducible MVA measurements similar to 2D planimetry performed by experienced operators. Thus, 3D-TEE could be considered as a second-line alternative tool for the evaluation of MS severity in patients with poor echocardiographic windows or for team less accustomed to evaluate MS patients.
No takes yet. Share an insight, caveat, or question.
Dreyfus et al. (2011) studied this question.