Key result
Mitral balloon valvotomy in pregnant women with severe mitral stenosis increased mitral valve area from 0.90 to 1.97 cm2 and decreased mean gradient to 5.5 mmHg.
Why the study?
Does mitral balloon valvotomy improve echocardiographic and clinical outcomes in pregnant women with severe mitral stenosis?
Observational (n=23)
Does mitral balloon valvotomy improve echocardiographic and clinical outcomes in pregnant women with severe mitral stenosis?
Mitral balloon valvotomy during the second trimester of pregnancy in women with severe mitral stenosis provides significant immediate hemodynamic improvement and satisfactory long-term maternal and fetal outcomes.
Answers are grounded in this paper and cite their sources.
Associated with acute hemodynamic gains in pregnant women with severe mitral stenosis; extends observational data but leaves open need for randomized confirmation.
Background and aim of the study The study aim was to examine the long-term outcome (nine years) of mitral balloon valvotomy in pregnant patients with severe mitral stenosis. Methods Twenty-three patients with severe, symptomatic (NYHA class III/IV) mitral stenosis underwent material balloon valvotomy using an lnoue balloon technique during the second trimester of their pregnancy; mean follow up was 5.1 ± 2.8 year (range: 1–9 years). Results The procedure was successful in all patients. Immediately after valvotomy, the Doppler-derived mitral valve area increased from 0.90 ± 0.18 to 1.97 ± 0.36 cm 2 ( p < 0.0001), and the transmitral mean gradient decreased from ‘15.7 ± 4.7 to 5.5 ± 1.6 mmHg ( p < 0.0001). Four patients had mild worsening of mitral regurgitation, and six developed insignificant interatrial communication immediately after valvotomy. There was no other morbidity or mortality. Patients showed a significant improvement in mean NYHA class Twenty-two patients had normal deliveries; one cesarean section in week 36 resulted in stillbirth. No developmental abnormalities were seen in the babies. At long-term follow up of mothers, the mitral valve area was 1.8 ± 0.52 cm 2 , restenosis developed in three patient (16%). One baby died at one week from sudden infant death syndrome, one at eight months from pneumonia. All other children showed normal growth, development and speech for their age. Conclusion Mitral balloon valvotomy using the Inoue balloon technique can provide satisfactory immediate and long-term outcome in pregnant patients with severe mitral stenosis.
No takes yet. Share an insight, caveat, or question.
Mohamed Fawzy (2014) conducted an observational in Severe mitral stenosis in pregnancy (n=23). Mitral balloon valvotomy using Inoue balloon technique was evaluated on Doppler-derived mitral valve area and transmitral mean gradient (p=<0.0001). Mitral balloon valvotomy in pregnant women with severe mitral stenosis increased mitral valve area from 0.90 to 1.97 cm2 and decreased mean gradient to 5.5 mmHg.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: