Answers are grounded in this paper and cite their sources.
A near-infrared broadband cavity-enhanced sensor system was demonstrated for the first time using an energy-efficient light emitting diode (LED) with a central emission wavelength at 1650 nm and a light power of ∼16 mW. A portable absorption gas cell was designed for realizing a compact and stable optical system for easy alignment. An ultrashort 8-cm-long cavity was fabricated consisting of two mirrors with a ∼99.35% reflectivity. Methane (CH 4 ) measurement was performed employing two detection schemes, i.e., NIRQuest InGaAs spectrometer and scanning monochromator combined with phase-sensitive detection. Retrieval of CH 4 concentration was performed using a least-squares fitting algorithm. Sensitivities (i.e., minimum detectable absorption coefficient) were achieved of 1.25 × 10 –6 cm –1 for an averaging time of 45 s using the NIRQuest InGaAs spectrometer and 1.85 × 10 –6 cm –1 for an averaging time of 8 min using the scanning spectrometer in combination with lock-in detection. Field monitoring of CH 4 gas leakage was performed using the NIRQuest spectrometer. Multigas sensing of CH 4 and acetylene (C 2 H 2 ) was carried out simultaneously using the high-resolution scanning spectrometer. A linear response of the retrieved concentration level versus nominal value was observed with a large dynamic range, demonstrating the reliability of the compact LED-based near-infrared broadband cavity-enhanced absorption spectroscopy (NIR-IBBCEAS) for multigas sensing applications.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: