Answers are grounded in this paper and cite their sources.
The spectral response of the dual resonant peaks of a 100 µm period fibre grating to surrounding refractive index (SRI) from n = 1 to 1.74 has been investigated. The two peaks were found to shift in opposite directions over –180 and +300 nm, respectively, as the SRI changed. A novel chemical sensing scheme with enhanced sensitivity based on the measurement of the separation of the two peaks instead of a shift in a single peak is also presented.
No takes yet. Share an insight, caveat, or question.
Shu et al. (1999) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: