Why the study?
Does aortic root volume measurement improve the prediction of contained aortic annulus rupture in patients undergoing balloon-expandable TAVR?
Does aortic root volume measurement improve the prediction of contained aortic annulus rupture in patients undergoing balloon-expandable TAVR?
Aortic root volume measurement, particularly in a two-step approach with annulus diameter, improves the prediction and potential avoidance of annulus rupture during balloon-expandable TAVR.
Answers are grounded in this paper and cite their sources.
May aid pre-TAVR annulus rupture risk stratification; leaves open prospective validation before practice change.
BACKGROUND: Aortic annulus rupture is a rare, but potentially fatal complication of transcatheter aortic valve replacement (TAVR), especially when it occurs by balloon-expandable devices. In order to improve the predictability of procedures and avoid ruptures we investigated whether or not the aortic root volume measures is a useful indicator of risk, and if it could be useful for the prosthesis size selection. METHODS AND RESULTS: From a retrospective series of 172 TAVR patients, seven experienced contained aortic annulus ruptures. The receiver operating curves were used to illustrate sensitivity and specificity of the different aortic annulus size and aortic root volume measures. The annulus area oversizing of ≥20% resulted in a sensitivity of 100%, specificity of 55.76%, and positive predictive value (PPV) of 8.75%. In patients receiving 26 mm prostheses, the aortic root volume (ARV <13600 mm(3)) provided a better specificity and PPV (79.63 and 18.52%, respectively). A two-step testing procedure considering the area derived average annulus diameter (Darea <23 mm) as a first separating parameter and then the ARV (<13,600 mm(3)) as a further indicator showed the most promising results with the PPV of 31.25%. Regardless of the procedure steps no false negative results were predicted. CONCLUSIONS: Our data show that the ARV provides a better predictive value for correct prosthesis sizing than established annulus measurements, especially in 'borderline' annuli. We suggest a two-step testing procedure for prostheses size selection, considering Darea and ARV to minimize the risk of annulus rupture. Prospective studies and examination of larger datasets are warranted to confirm these findings.
No takes yet. Share an insight, caveat, or question.
Reinöhl et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: