Why the study?
High degree cardiac conduction disturbances remain a major complication after TAVR, especially with self-expandable valves.
What is the incidence and what are the predictors of high degree cardiac conduction disturbances in patients with severe aortic stenosis undergoing TAVR with new generation self-expanding valves?
What is the incidence and what are the predictors of high degree cardiac conduction disturbances in patients with severe aortic stenosis undergoing TAVR with new generation self-expanding valves?
New generation self-expanding valves for TAVR are associated with a high rate of conduction disturbances, with valve recapture and deeper implantation being significant predictors of these complications.
Answers are grounded in this paper and cite their sources.
High HDCD rates after self-expanding TAVR may warrant procedural caution with recapture and depth; leaves open prospective validation of modifiable predictors.
BACKGROUND: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR. METHODS AND RESULTS: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro (n = 130), Acurate-neo (n = 79), Portico (n = 75) and Allegra (n = 60)] were included. An analysis of baseline, post-TAVR and pre-discharge ECG and procedural aspects were centrally performed. A significant increase in baseline PR interval (169.6 ± 28.2 ms) and QRS complex width (101.7 ± 25.9 ms) was noted immediately post-TAVR (188.04 ± 34.49; 129.55 ± 30.02 ms), with a partial in-hospital reversal (179.4 ± 30.1; 123.06 ± 30.94 ms), resulting in a net increase at hospital discharge of 12.6 ± 38.8 ms and 21.4 ± 31.6 ms (p < 0.001), respectively. The global incidence of new onset persistent HDCD at hospital discharge was 46.3%, with 17.7% of patients requiring PPM. Independent predictors of new onset HCDC at hospital discharge were valve recapture (OR: 2.8; 95% IC: 1.1-7.2, p = 0.033) and implantation depth ≥ 6 mm (OR: 1.9 05% IC 1.1-3.3, p = 0.015), while higher implantation (<3 mm (OR: 0.3, 95% IC 0.1-0.7, p = 0.014) and use of Acurate-Neo valve (OR: 0.4; 95% IC 0.2-0.8, p = 0.009) were protective factor. CONCLUSIONS: New generation self-expanding aortic valves were associated with a significant increase in PR and QRS interval at hospital discharge leading to a very high rate of HDCD. While valve recapture and implantation depth were independent predictors for the occurrence of HDCD, use of Accurate-Neo valve was a protective factor.
No takes yet. Share an insight, caveat, or question.
Castro‐Mejía et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: