This preclinical study describes the development of a transcarotid coronary arteriography method in dogs, highlighting techniques for catheter placement and evaluation of physiologic effects.
Answers are grounded in this paper and cite their sources.
Preclinical transcarotid catheter technique shown in dogs; leaves open translation to human coronary arteriography.
New surgical approaches (1, 2, 9) offer some hope to the many persons suffering from occlusive disease of the coronary arteries. The rational selection of patients for surgery and, indeed, the outcome of the operation itself will certainly benefit by a reliable, precise method of preoperative localization of diseased segments of these vessels and the clarification of the state of the collateral circulation, if such exists. Many investigators (3, 4, 5, 9, 12, 13, 15) have reported methods of radiographically visualizing the coronary circulation in living animals, and others (7, 8, 10, 15, 17, 18) have used varying technics in man. Recognizing the need for a practical clinical method of portraying the coronary artery circulation, our group decided to approach this goal by modifying our previously reported method of aortic valvulography (14), inasmuch as this technic was already an accepted and useful tool in our institution. It is the purpose of this paper to describe the method of coronary arteriography worked out in the animal laboratory, with special emphasis upon the physiologic effects. Method of Study In our animal studies 350 injections were performed in 50 mongrel dogs. No attempt was made to appraise contrast materials, our efforts being directed toward evaluating the opacification of the coronary arteries as we varied catheters, speed of injection, injection pressure, amount and concentration of contrast medium, phase of the cardiac cycle during which the injection was initiated, etc. During the evaluation of these variables, we were also interested in the electrocardiographic changes occurring during and after all injections. The right common carotid artery was used as the point of entry for the catheter, which was then passed through the brachiocephalic trunk into the ascending aorta. Early in our experiments the tip of the catheter was placed in the desired supravalvular region under fluoroscopic control. After some experience, it was learned that the location of the catheter tip could be accurately estimated by virtue of the appearance of a rather vigorous to-and-fro movement-2 to 3 mm.-of the entire catheter as it approached the valve region. If the catheter was inadvertently passed into the descending aorta, this movement was minimal and did not increase in amplitude. A very noticeable increase in amplitude as the catheter was gently advanced through the incision in the right carotid artery was proof that the tip was approaching the aortic valve. Types of Catheter Our previous investigations (14) had shown that the use of a single-side-opening, closed-end catheter precluded the loss of contrast material through the normal aortic valve into the left ventricle. With the transcarotid approach, however, the tip of the catheter usually became located near the left coronary artery ostium because of the normal anatomic factors in dogs.
No takes yet. Share an insight, caveat, or question.
Nelson et al. (1960) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: