Why the study?
Does epicardial ultrasound-guided direct cannulation of the true lumen improve perfusion during surgery for acute type A aortic dissection complicated by malperfusion?
Does epicardial ultrasound-guided direct cannulation of the true lumen improve perfusion during surgery for acute type A aortic dissection complicated by malperfusion?
Epicardial ultrasound-guided direct cannulation using a Seldinger technique may help achieve true lumen perfusion during surgery for acute type A aortic dissection complicated by malperfusion.
Should not yet change cannulation practice in malperfusion; leaves open the value of this technique pending prospective data.
During surgery for acute type A aortic dissection, malperfusion may occur during cardiopulmonary bypass. Retrograde perfusion trough femoral cannulation is considered a predisposing factor. However, this may occur even with antegrade perfusion, because of the presence of multiple flaps or compression of the true lumen by the false lumen. In this particular setting, the aim is to reach a perfusion of the true lumen of the dissected aorta. A technique of epicardial ultrasound-guided direct cannulation of the dissected aorta’s true lumen by a Seldinger technique may help in those cases. We describe the technique with particular interest to the epicardial ultrasound control and the type of arterial cannula to be inserted by the Seldinger technique.
No takes yet. Share an insight, caveat, or question.
Lentini et al. (2009) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: