Electrical aspects of an rf planar magnetron discharge in noble gases at pressures below 50 mTorr are discussed. The electrical parameters of the experimental device are measured by a diagnostic system consisting of two probes, a capacitive voltage divider and a current loop. The measurements of the rf current and voltage and the fast Fourier transform treatment of recorded signals are used to verify the validity of the `subtraction' method in order to estimate the power deposited into the plasma. This technique shows a better power coupling with a metallic target, up to 90% of the rf delivered power, than for an insulating target for which the power efficiency hardly reaches 50%. In addition, the elementary mechanisms sustaining the rf planar magnetron discharge are analysed. A transition from a combination of α (`wave-riding') and γ (secondary electron emission) regimes above a critical pressure to an α dominant regime at very low pressure is pointed out. This phenomenon is explained by the results of a particle-in-cell Monte Carlo collision simulation.