Clinicians should be aware of the potential for cardiac tamponade as a complication when removing temporary transvenous pacing wires and pericardial drains.
Answers are grounded in this paper and cite their sources.
May warrant close monitoring after TVP wire and drain removal; hypothesis-generating case leaves incidence and prevention open.
A patient presented for an elective transcatheter aortic valve replacement with temporary transvenous pacing (TVP) wires placement per protocol. On postoperative day 1, the patient remained stable, so the wires were subsequently removed, after which the patient acutely decompensated, with transthoracic echocardiography revealing pericardial effusion. Emergent pericardiocentesis was performed, and a pericardial drain was placed. Three days later, the drain was removed; again, the patient acutely decompensated, requiring another emergent pericardiocentesis. Despite the relatively benign nature of TVP wires and pericardial drains, the possibility of cardiac tamponade should be kept in mind as a potential complication when they are being removed.
No takes yet. Share an insight, caveat, or question.
Suthar et al. (2017) studied this question.