Computer analysis for dynamic domain size variation in grain-oriented 3% Si-Fe tape-wound cores is, first, presented by using a principle of minimization of total free energy, the sum of magnetostatic energy at grain boundaries and dynamic bowing domain-wall energy, and by using quasi-static permeability as a function of peak flux density. Second, iron losses per cycle, Wi/f, in the cores are calculated and compared with experimental results: the origin of 'anomalous loss' is quantitatively clarified; Wi/f becomes minimum at certain value of tape thickness; Wi/f is smaller at 'voltage excitation'; and instantaneous domain-wall profiles and energy loss are illustrated. An experimental result for reduction of iron losses by scratching method is also shown.
No takes yet. Share an insight, caveat, or question.
Mohri et al. (1976) studied this question.