Key result
Modifying step frequency for variable height objects during a virtual YMCA step test produced reliable heart rate responses between small (101 BPM) and large (103 BPM) steps.
Why the study?
The standard YMCA step test requires a prescribed step height that is difficult to implement in a telehealth setting.
Does modifying step frequency for variable step heights provide reliable heart rate values during virtual cardiorespiratory fitness testing in young healthy participants?
RCT (n=40)
randomized cross-over
Does modifying step frequency for variable step heights provide reliable heart rate values during virtual cardiorespiratory fitness testing in young healthy participants?
Modifying step frequency to account for varying step heights allows for reliable heart rate responses during virtual YMCA step testing, facilitating telehealth fitness assessments.
Answers are grounded in this paper and cite their sources.
Reliable self-palpated HR across step heights with adjusted frequency; extends virtual YMCA testing for telehealth fitness assessment.
The YMCA step test uses a prescribed step height which is difficult in a telehealth setting. Examine a modification of the YMCA step test allowing for the use of preexisting in-home objects of variable height as the “step” in a virtual environment. Young healthy participants (n = 40) performed step tests with a small and large object of their choosing within their home in a randomized cross-over study. The stepping frequency was modified for each step height using an established metabolic formula to match estimated exercising VO2 of the YMCA step test. Post-exercise self-palpated heart rate from the small (average 101 ± 23 BPM) vs large (103 ± 23 BPM) step tests were correlated (r = 0.865, p < .001) with good reliability (ICC = 0.865) and within-participant coefficient of variation of 6.8%. Modifying step frequency to account for the varying heights of objects used as “steps” results in reliable heart rate responses to the YMCA step test.
No takes yet. Share an insight, caveat, or question.
Matthews et al. (2021) conducted an RCT in Healthy (n=40). Modified YMCA step test with small object vs. Modified YMCA step test with large object was evaluated on Post-exercise self-palpated heart rate (r = 0.865, p=< .001). Modifying step frequency for variable height objects during a virtual YMCA step test produced reliable heart rate responses between small (101 BPM) and large (103 BPM) steps.
Synapse has enriched 10 related papers. Consider them for comparative context: