Answers are grounded in this paper and cite their sources.
Gold gratings with spatial periods of 0.3 and 0.2 μm have been fabricated in thicknesses of 0.6 and 0.25 μm, respectively, and used in x-ray spectroscopy and spatial-period-division. Fabrication techniques included: holographic lithography, shadowing, x-ray lithography, and gold microplating. Control of linewidth to tolerance of the order of 10 nm has been demonstrated for gratings of 0.2 μm period. A high resolution imaging spectrometer, composed of a 22× Wolter x-ray microscope in conjunction with a gold transmission grating, was tested. At a wavelength of 0.69 nm, a resolving power, λ/Δλ, of 200 was demonstrated. Resolution in this case was source-size limited. Gratings of 99.5 nm period were exposed in PMMA by x-ray (λ = 4.5 nm) spatial-period-division.
No takes yet. Share an insight, caveat, or question.
Hawryluk et al. (1981) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: