Key result
MCE-derived transmural blood flow ratios correlate strongly with radiolabeled microsphere measurements.
Answers are grounded in this paper and cite their sources.
Demonstrates that ultrasound microbubble destruction-replenishment accurately measures transmural myocardial perfusion in dogs, highlighting a noninvasive method for detecting regional ischemia.
BACKGROUND: We hypothesized that by using our newly defined method of destroying microbubbles and measuring their rate of tissue replenishment, we could assess the transmural distribution of myocardial perfusion. METHODS AND RESULTS: We studied 12 dogs before and after creation of left anterior descending coronary artery stenoses both at rest and during hyperemia (n=62 stages). Microbubbles were administered as a constant infusion, and myocardial contrast echocardiography (MCE) was performed with the use of different pulsing intervals. The video intensity versus pulsing interval plots derived from each myocardial pixel were fitted to an exponential function: y=A(1-ebetat), where A reflects microvascular cross-sectional area (or myocardial blood volume), and beta reflects mean myocardial microbubble velocity. The product A . beta represents myocardial blood flow (MBF). Average values for these parameters were derived from the endocardial and epicardial regions of interest placed over the left anterior descending coronary artery bed. Radiolabeled microsphere-derived MBF was also measured from the same regions. There was poor correlation between radiolabeled microsphere-derived MBF and A-endocardial/epicardial ratios (EER) (r=0.46). The correlation with beta-EER was better (r=0. 69, P<0.01). The best correlation with radiolabeled microsphere-derived MBF-EER was noted with A . beta-EER (r=0.88, P<0. 01). CONCLUSIONS: The transmural distribution of myocardial perfusion can be accurately assessed with MCE with the use of our newly described method of tissue replenishment of microbubbles after their ultrasound-induced destruction. In the model studied, an uncoupling of the transmural distribution of MBF and myocardial blood volume was observed during reversal of the MBF-EER.
No takes yet. Share an insight, caveat, or question.
Linka et al. (1998) studied Left anterior descending coronary artery stenosis (n=12). Myocardial contrast echocardiography (MCE) with constant microbubble infusion vs. Radiolabeled microsphere-derived myocardial blood flow (MBF) was evaluated on Correlation of MCE-derived A . beta endocardial/epicardial ratio (EER) with radiolabeled microsphere-derived myocardial blood flow (MBF)-EER (r=0.88, p=<0.01). Myocardial contrast echocardiography-derived A. beta endocardial/epicardial ratios strongly correlated with radiolabeled microsphere-derived myocardial blood flow ratios.
Synapse has enriched 10 related papers. Consider them for comparative context: