Key result
High-resolution micro-diffusion tensor imaging detected significant differences in fractional anisotropy and mean diffusivity across the media layer in intact carotid arteries.
Why the study?
Does high-resolution micro-diffusion tensor imaging at 7 T detect structural differences between intact and open cut carotid artery tissue?
Does high-resolution micro-diffusion tensor imaging at 7 T detect structural differences between intact and open cut carotid artery tissue?
Answers are grounded in this paper and cite their sources.
High-resolution micro-diffusion tensor imaging at 7 T can detect local structural changes in intact arterial tissue, providing potential imaging markers for the diagnosis of atherosclerosis and aneurysms.
in less than 2 h of scan time. A parameter selective single shell (128 directions) diffusion-encoding scheme based on Stejskel-Tanner sequence with echo-planar imaging (EPI) readout was used. EPI segmentation was used to reduce the echo time (TE) and to minimise the susceptibility-induced artefacts. The study utilised the dMRI analysis with diffusion tensor imaging (DTI) framework to investigate structural heterogeneity in intact arterial tissue and to quantify variations in tissue composition when the tissue is cut open and flattened. For intact arterial samples, the region of interest base comparison showed significant differences in fractional anisotropy and mean diffusivity across the media layer (p < 0.05). For open cut flat samples, DTI based directionally invariant indices did not show significant differences across the media layer. For intact samples, fibre tractography based indices such as calculated helical angle and fibre dispersion showed near circumferential alignment and a high degree of fibre dispersion, respectively. This study demonstrates the feasibility of fast dMRI acquisition with ultra-high spatial and angular resolution at 7 T. Using the optimised sequence parameters, this study shows that DTI based markers are sensitive to local structural changes in intact arterial tissue samples and these markers may have clinical relevance in the diagnosis of atherosclerosis and aneurysm.
No takes yet. Share an insight, caveat, or question.
Shahid et al. (2017) studied Carotid artery tissue. Intact arterial tissue vs. Open cut flat samples was evaluated on Fractional anisotropy and mean diffusivity across the media layer (p=<0.05). High-resolution micro-diffusion tensor imaging detected significant differences in fractional anisotropy and mean diffusivity across the media layer in intact carotid arteries.