Key result
MitraClip is linked to ~26 mL lower LVEDV at 1 year in functional MR.
Why the study?
The study was conducted to identify echocardiographic predictors of clinical response and left ventricular reverse remodelling in patients with functional mitral regurgitation treated with MitraClip.
Does transcatheter mitral valve repair with MitraClip improve left ventricular reverse remodelling and myocardial work indices at 1 year compared to optimal medical therapy alone in high surgical risk patients with functional mitral regurgitation, and can baseline strain indices predict remodelling?
Cohort (n=86)
Blinded
No
Does transcatheter mitral valve repair with MitraClip improve left ventricular reverse remodelling and myocardial work indices at 1 year compared to optimal medical therapy alone in high surgical risk patients with functional mitral regurgitation, and can baseline strain indices predict remodelling?
Preserved baseline global longitudinal strain (GLS <= -8.65%) and global constructive work (GCW >= 846 mmHg%) predict left ventricular reverse remodelling 1 year after MitraClip repair in patients with functional mitral regurgitation, helping refine patient selection.
Answers are grounded in this paper and cite their sources.
Baseline GLS and GCW may refine MitraClip selection for reverse remodelling in functional MR; leaves open prospective validation versus medical therapy.
AIMS: The purpose of this study is to identify echocardiography predictors of clinical response and reverse left ventricular (LV) remodelling in patients with functional mitral regurgitation (FMR) treated with MitraClip. METHOD AND RESULTS: We retrospectively analysed 86 high surgical risk patients with severe FMR; of those, 58 were implanted a MitraClip, and 28 received medical treatment and served as controls. At baseline and at 1-year follow-up, we performed clinical and echocardiography evaluation to assess global longitudinal strain (GLS) and myocardial work [global work index (GWI), global constructive work (GCW), global wasted work (GWW), global work efficiency (GWE)]. Mitral regurgitation was significantly reduced after MitraClip implantation (3.7 ± 0.4 vs. 1.7 ± 0.8, P < 0.001), and the procedure was associated with improvement in brain natriuretic peptide levels (980 ± 1027 vs. 420 ± 338 pg/mL, P < 0.001), New York Heart Association class status (3.2 ± 0.55 vs. 2.0 ± 0.6, P < 0.001), 6-min walking test (233 ± 154 vs. 286 ± 114 m, P = 0.01) at follow-up and reduction of left ventricle end-systolic (LVESV) and left ventricle end-diastolic volumes (LVEDV) (152 ± 68 vs. 136 ± 43 mL, P = 0.004 & 219 ± 74 vs. 193 ± 66 mL, P = 0.001, respectively). MitraClip procedure was associated with improvement of LV performance and significant increase of GWI (607 ± 282 vs. 650 ± 260 mmHg%, P = 0.045) and GCW (854 ± 288 vs. 949 ± 325 mmHg%, P < 0.001). Baseline ejection fraction (EF), GLS, GWI, GCW, and effective regurgitant orifice area were the variables that were associated with reduction of LVEDV 1 year after intervention (P < 0.05 for all) and baseline GCW of the LV was the only variable associated with reduction of LVESV (P = 0.002). Receiver operating characteristic curve analysis identified that a GLS cut-off value of -8.65% (AUC 0.815, P = 0.007) was associated with a 20% reduction of the LVEDV with a sensitivity and specificity of 72% and 70%, respectively, and that a GCW cut-off value of 846 mmHg% (AUC 0.759, P = 0.007) was associated with a 10% reduction of LVESV with sensitivity and specificity 79% and 74%, respectively. CONCLUSIONS: Mitral valve repair with MitraClip has positive clinical and echocardiographic impact in patients with FMR 1 year after implantation. Preserved GLS and GCW values appear to be associated with LV reverse remodelling post intervention.
No takes yet. Share an insight, caveat, or question.
Παπαδόπουλος et al. (2020) conducted a cohort in Moderate-to-severe or severe functional mitral regurgitation with reduced LV contractility (n=86). MitraClip transcatheter edge-to-edge mitral valve repair vs. Optimal medical treatment alone was evaluated on Left ventricular end-diastolic volume (LVEDV) at 1-year follow-up (p=0.01). MitraClip implantation reduced LVEDV and LVESV at 1 year in functional MR, predicted by baseline GLS <=-8.65% and GCW >=846 mmHg%.