Why the study?
The study aimed to evaluate the feasibility and safety of the ValveClasp system, a novel arm-width-expandable TEER device designed to treat patients with only one clip more frequently.
Is the novel arm-width-expandable ValveClasp system safe and feasible for treating severe mitral regurgitation?
Is the novel arm-width-expandable ValveClasp system safe and feasible for treating severe mitral regurgitation?
The novel arm-width-expandable ValveClasp TEER system demonstrated initial safety and feasibility in both porcine models and a small first-in-human cohort.
Early feasibility supports larger trials; leaves open clinical efficacy and durability of the expandable-arm TEER clip.
Background The ValveClasp system is a novel transcatheter edge‐to‐edge repair (TEER) device with an arm‐width‐expandable clip that allows treatment of patients with only one clip more frequently. Objectives This study aimed to evaluate the feasibility and safety of a novel TEER device in porcine models and patients. Methods Fourteen young adult pigs were enrolled. A clip with an expanded arm was implanted under epicardial echocardiography and fluoroscopy guidance. Five patients with at least moderate‐to‐severe mitral regurgitation underwent TEER using the ValveClasp system to test the safety and effectiveness of the device. Results The device success rate was 100% (14/14) in the animal experiments, and all clips were deployed at the A2P2 segments, forming a double‐orifice mitral valve. Gross observations on day 180 showed a wide and continuous tissue bridge between the leaflets. The acute procedural success rate was 100% (5/5). Only one clip was required in all patients, and all achieved effective postoperative endpoints (grade ≤2+). During 30‐day follow‐up, no adverse events occurred. All patients' vena Contracta width (from 8.04 0.71 mm to 3.84 ± 1.18 mm, p = 0.012), mitral regurgitation area (from 12.75 ± 3.13 cm2 to 3.50 ± 1.66 cm2, p = 0.008), and left ventricular end diastolic diameter (from 52.00 ± 2.92 mm to 46.00 ± 3.08 mm, p = 0.040) were considerably decreased, without obvious mitral stenosis. Conclusions The novel arm‐width‐expandable ValveClasp device is safe for TEER for treating severe mitral regurgitation.
No takes yet. Share an insight, caveat, or question.
Long et al. (2023) studied Moderate-to-severe mitral regurgitation (n=5). ValveClasp system was evaluated on Acute procedural success rate.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: