Key result
T2-based methods provided qualitatively improved high-resolution fat fraction images of the calf compared with the CSEI method, with the 2-parameter fit showing the best quantitative agreement.
Why the study?
Do T2-based methods provide improved high-resolution fat fraction images of the calf compared with chemical shift-encoded imaging in healthy volunteers?
Do T2-based methods provide improved high-resolution fat fraction images of the calf compared with chemical shift-encoded imaging in healthy volunteers?
T2-based methods can provide improved high-resolution fat fraction images of the calf compared with the standard chemical shift-encoded imaging method.
Offers a promising technical refinement for peripheral tissue characterization; leaves open whether this improved imaging translates to.
Chemical shift-encoded imaging (CSEI) is the most common magnetic resonance imaging fat–water separation method. However, when high spatial resolution fat fraction (FF) images are desired, CSEI might be challenging owing to the increased interecho spacing. Here, 3 T2-based methods have been assessed as alternative methods for obtaining high-resolution FF images. Images from the calf of 10 healthy volunteers were acquired; FF maps were then estimated using 3 T2-based methods (2- and 3-parameter nonlinear least squares fit and a Bayesian probability method) and CSEI for reference. In addition, simulations were conducted to characterize the performance of various methods. Here, all T2-based methods resulted in qualitatively improved high-resolution FF images compared with high-resolution CSEI. The 2-parameter fit showed best quantitative agreement to low-resolution CSEI, even at low FF. The estimated T2-values of fat and water, and the estimated muscle FF of the calf, agreed well with previously published data. In conclusion, T2-based methods can provide improved high-resolution FF images of the calf compared with the CSEI method.
No takes yet. Share an insight, caveat, or question.
Trinh et al. (2017) studied Healthy (n=10). T2-based methods (2- and 3-parameter nonlinear least squares fit and a Bayesian probability method) vs. Chemical shift-encoded imaging (CSEI) was evaluated on Qualitative improvement and quantitative agreement of high-resolution fat fraction images. T2-based methods provided qualitatively improved high-resolution fat fraction images of the calf compared with the CSEI method, with the 2-parameter fit showing the best quantitative agreement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: