Intravenous digital subtraction angiography (IV-DSA) combined with excretory urography was used to evaluate the renal anatomy of 100 potential living-related kidney donors. Each of the 100 patients underwent subsequent nephrectomy to verify the number and distribution of renal vessels. For the entire series, 71 patients had bilateral single, 2 bilateral multiple and 27 multiple renal arteries on one side determined by angiography. Eleven patients required standard catheter angiography due to inadequate IV-DSA studies. Four patients who had a single artery imaged by IV-DSA were found to have an additional vessel at the operation. The overall accuracy of IV-DSA to identify the number of renal vessels was 96% (85/89). The sensitivity of the exam was 100% (94/94) and the specificity was 67% (4/6). It is concluded that IV-DSA combined with excretory urography is a safe, cost effective, and suitable method to image the renal anatomy of potential kidney donors. Thus about 90% of donors can be spared the risks and inconvenience of standard angiography, and the donor evaluation can now be performed on an outpatient basis.
No takes yet. Share an insight, caveat, or question.
Flechner et al. (1985) studied this question.