Key result
The new Spline QT correction formula was minimally impacted by heart rate acceleration induced by atrial or ventricular pacing, whereas the Bazett formula showed marked heart rate dependency.
Why the study?
Does the new Spline QTc formula provide a more stable QTc measurement across varying heart rates compared to the Bazett formula during atrial and ventricular pacing?
Does the new Spline QTc formula provide a more stable QTc measurement across varying heart rates compared to the Bazett formula during atrial and ventricular pacing?
The new Spline QTc formula provides a stable QTc estimate across varying heart rates during pacing, outperforming the traditional Bazett formula.
Supports more stable QTc with Spline formula during pacing; leaves open prospective outcome validation before clinical adoption.
AIMS: To determine whether a new QTc calculation based on a Spline fit model derived and validated from a large population remained stable in the same individual across a range of heart rates (HRs). Second, to determine whether this formula incorporating QRS duration can be of value in QT measurement, compared to direct measurement of the JT interval, during ventricular pacing. METHODS: =30; 14 males) aged 51.9 ± 14.3 years were paced with decremental atrial followed by decremental ventricular pacing. RESULTS: The new QTc changed minimally with shorter RR intervals, poorly fit even a linear relationship, and did not fit a second-order polynomial. In contrast, the Bazett formula (QTcBZT) showed a steep and marked increase in QTc with shorter RR intervals. For atrial pacing data, QTcBZT was fit best by a second-order polynomial and demonstrated a dramatic increase in QTc with progressively shorter RR intervals. For ventricular pacing, the new QTc minus QRS duration did not meaningfully change with HR in contrast to the HR dependency of QTcBZT and JT interval. CONCLUSION: The new QT correction formula is minimally impacted by HR acceleration induced by atrial or ventricular pacing. The Spline QTc minus QRS duration is an excellent method to estimate QTc in ventricular paced complexes.
No takes yet. Share an insight, caveat, or question.
Nouraei et al. (2018) studied this question. New Spline QTc formula vs. Bazett formula (QTcBZT) and JT interval was evaluated on Stability of QTc calculation across a range of heart rates. The new Spline QT correction formula was minimally impacted by heart rate acceleration induced by atrial or ventricular pacing, whereas the Bazett formula showed marked heart rate dependency.