Answers are grounded in this paper and cite their sources.
It is found that the resonance cavity-lengths for transverse modes observed at 81.5 and 263.4 µm of an optically pumped far-infrared NH 3 laser agree well with existing theory. It is observed that the number of modes in the 81.5-µm line decreases from five to one with the increasing NH 3 pressure. This effect may be attributed to the pressure dependence of the high gain region in the far-infrared cavity. The large gain coefficient of this laser is discussed. The observed strong correlation between the 81.5- and the 263.4-µm lines is reasonably explained by a simple model based on the cascade transition, implying that in this experiment the collision-induced transition is masked by the cascade transition.
No takes yet. Share an insight, caveat, or question.
Yamanaka et al. (1974) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: