Answers are grounded in this paper and cite their sources.
In charge-pumping (CP) measurements of 4H-SiC n-channel MOSFETs, a geometric component (GC) unrelated to interface traps can cause overestimation of interface-trap density. We investigated the channel-length and gate-pulse fall-time dependences of CP current using experiments and transient TCAD simulations. The CP current density increased with channel length at short fall times, whereas this increase was suppressed at longer fall times. Spatial distributions of electron concentration, electron transport, and Shockley–Read–Hall recombination revealed residual electrons near the channel center and recombination in the bulk region during the gate-voltage fall. These observations are consistent with the proposed mechanism in which recombination involving residual electrons contributes to GC generation. By comparing the characteristic electron diffusion length with the distance to the source/drain regions, we derived an approximate critical channel length, L crit = 2 D n t f, which explains the observed GC generation and suppression trends.
No takes yet. Share an insight, caveat, or question.
Oi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: