Why the study?
Does a primary repair technique using Teflon felt support improve outcomes in patients with ascending aortic dissection?
Does a primary repair technique using Teflon felt support improve outcomes in patients with ascending aortic dissection?
Answers are grounded in this paper and cite their sources.
Primary repair of ascending aortic dissection using a Teflon felt-supported technique is associated with a 10% mortality rate and provides stable outcomes over a 2-year follow-up.
A primary repair technique was used to treat 20 cases of dissection of the ascending aorta. The group consisted of 13 men and 7 women with an average age of 65 years. Dissection complicated cardiac surgery in 13, was spontaneous in 6, and was traumatic in 1. The repair included a noncircumferential aortotomy at the site of the primary tear sparing the posterior wall, followed by Teflon felt-supported repair of the dissected layers, and wrapping of the aorta with a Teflon felt pad. Concomitant procedures included coronary bypass grafts in 12, valve surgery in 3, and closure of infarction-related ventricular septal defect in 1. Two patients died (mortality 10%). Postoperative complications were relatively frequent in the remaining 18 patients. All survivors were stable for an average follow-up period of 2 years. Compared with replacement grafting, this procedure is less time-consuming and probably provides better stability of the ascending aorta.
No takes yet. Share an insight, caveat, or question.
Bashour et al. (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: