Answers are grounded in this paper and cite their sources.
A Monte Carlo method has been developed for calculating dose distributions within a fluid phantom irradiated by an external heterogeneous x-ray beam. The method utilized a three-dimensional array of numerically-described cuboids (voxels) to provide phantom anatomy, with vector concepts to determine photon flight paths, locations, and interaction points, regardless of materials located within the phantom. Using a homogeneous water phantom and an 80 kVp x-ray beam, results of 196488 photon histories per cm2 were compared with a measured dose distribution. Discrepancies appeared to be the result of experimental error in the measured dose distribution. χ2 tests indicated that they were not statistically significant.
No takes yet. Share an insight, caveat, or question.
Pujol et al. (1982) studied this question.