Answers are grounded in this paper and cite their sources.
A conceptual-scale continuous pyroelectric converter was constructed and tested. Low-grade heat was converted to electricity using a single 25 @ m thick 60%-40% P(VF 2 -TrFE) copolymer film. A pyroelectric conversion cycle conceived by Olsen was adopted; external control voltage was cycled between high and low in synchronization with cycling of film temperature. Control voltage was cycled between 100 and 1200V and heat source temperature between 30°C and 82°C. Conversion cycle time was varied between 3 and 4s. The ratio of electrical output to electrical input ranged between 1.2-1.5. Experimental data showed that the energy density was between 15-52 J/L of copolymer used. The pyroelectric converter system and preliminary data are presented.
No takes yet. Share an insight, caveat, or question.
Michio Ikura (2002) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: