Answers are grounded in this paper and cite their sources.
D.C. SQUIDS of cylindrical geometry have been fabricated using Nb-NbOx-Pb tunnel junctions. The SQUIDs can be thermally cycled repeatedly and cooled in the earth's magnetic field without significant loss of performance. Flux resolution of3 × 10⁻⁵ φₒ/√Hzabove a frequency of 1 Hz has been achieved through optimization of electronic circuitry and careful shielding. Fluctuations and drift in the temperature of the helium bath are found to be the major source of long-term SQUID noise. With a simple temperature stabilizer, drift has been reduced to less than8 × 10⁻⁵ φₒ/hr over a three hour period.
No takes yet. Share an insight, caveat, or question.
Clarke et al. (1975) studied this question.