Key result
Aortic valve replacement with Carpentier-Edwards pericardial valves yields ~88% 15-year freedom from SVD reoperation.
Why the study?
There are few data regarding the actual long-term durability of bioprosthetic valves in Japanese patients undergoing aortic valve replacement.
Cohort (n=574)
Yes
The Carpentier-Edwards pericardial valve demonstrates excellent long-term durability in Japanese patients, confirming current guidelines that recommend bioprostheses for patients aged ≥65 years.
Answers are grounded in this paper and cite their sources.
Supports bioprosthetic durability in Japanese AVR cohorts; leaves open generalizability and guideline impact.
BACKGROUND According to the Japanese Circulation Society guidelines, a bioprosthesis is recommended for aortic valve replacement (AVR) in patients aged ≥65 years who have no risk factors for thromboembolism. There are few data, however, regarding the actual durability of bioprosthetic valves in Japanese patients. The purpose of this study was to assess the long-term durability of Carpentier-Edwards pericardial (CEP) valves in Japanese AVR patients, and to assess the risk factors for reoperation due to structural valve deterioration (SVD). METHODS AND RESULTS From 1986 to 2001, a total of 591 patients underwent AVR with CEP valves in 9 hospitals. Of these, 574 patients (mean age, 71.9±8.5 years) were analyzed in this study. There were 26 in-hospital deaths (4.5%). The 10-year follow-up rate was 82.6% and the median follow-up time was 9.2 years. Freedom from reoperation due to SVD was 99.5%, 96.7%, and 87.5% at 5, 10, and 15 years, respectively. Factors that raised the risk of reoperation due to SVD included younger age at operation and history of prior operation. In patients aged ≥65 years, freedom from reoperation due to SVD was 94.4% at 15 years. CONCLUSIONS The durability of CEP valves in patients with AVR was excellent, especially in elderly patients. Thus, it seems appropriate to follow the current Japanese Circulation Society recommendations for the use of bioprosthetic valves.
No takes yet. Share an insight, caveat, or question.
Minakata et al. (2014) conducted a cohort in Aortic valve disease requiring replacement (n=574). Carpentier-Edwards pericardial valve was evaluated on Freedom from reoperation due to structural valve deterioration (SVD) at 15 years. In Japanese patients undergoing aortic valve replacement with the Carpentier-Edwards pericardial valve, freedom from reoperation due to structural valve deterioration was 87.5% at 15 years.
Synapse has enriched 10 related papers. Consider them for comparative context: