Why the study?
Does a small valve area index (<1.9 cm2/m2) increase 30-day mortality in adult patients undergoing mitral valve replacement with a mechanical prosthesis?
Does a small valve area index (<1.9 cm2/m2) increase 30-day mortality in adult patients undergoing mitral valve replacement with a mechanical prosthesis?
A small mitral valve area index (<1.9 cm2/m2) is strongly and independently associated with increased 30-day mortality after mitral valve replacement, primarily due to congestive heart failure.
Small mitral valve area index associated with higher 30-day mortality after mechanical MVR; leaves open whether optimized sizing improves outcomes.
OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis was measured, focusing on the lower tail of the normal distribution curve of the prosthetic valve area index. For the calculation of the geometric valve area index (cm(2)/m(2) body surface area), we used specifications for the geometric valve area supplied by the manufacturer. The cut-off value of the 10th percentile of the valve area index was 1.919 cm(2)/m(2). The study population consisted of 428 adult patients who underwent mitral valve replacement by a Medtronic Hall (n=270, 63%) or a St. Jude Medical prosthesis (n=158, 37%). The size of the valves implanted ranged from 25 mm to 31 mm. The valve area index showed a normal distribution curve ranging from 1.43 to 2.98 cm(2)/m(2) with a mean of 2.2 cm(2)/m(2). Group 1 (n=33) had a valve area index <1.9 cm(2)/m(2) and group 2 (n=395), > or =1.9 cm(2)/m(2). The 30-day mortality was higher in group 1 than in group 2 (18.2 vs. 4.1%, P=0.005). Multivariate logistic regression analysis of the determinants of the 30-day mortality rendered a small valve area index (<1.9 cm(2)/m(2)) as an independent risk indicator: relative risk 4.3 (95% CI 1.6-9.5; P=0. 0043). The difference in overall survival between the two groups was entirely due to the high 30-day mortality in the patients with small valve area indices, congestive heart failure being the main cause of death. CONCLUSIONS: By concentrating on the extreme lower tail of the normal distribution of the valve area index, a strong and independent relation was found between relatively small valves (valve area index <1.9 cm(2)/m(2)) and 30-day mortality. We found no influence of valve size on late mortality beyond the first 30 days.
No takes yet. Share an insight, caveat, or question.
Yazdanbakhsh et al. (2000) studied this question.