Key result
Zero-fluoroscopy catheter ablation using three-dimensional mapping achieved a 100% immediate success rate with no complications in patients with various tachyarrhythmias.
Why the study?
Fluoroscopy during catheter ablation exposes patients and medical personnel to ionizing radiation risks, prompting alternative zero-fluoroscopy techniques using electroanatomical mapping and intracardiac ultrasound.
Does zero-fluoroscopy catheter ablation achieve immediate success and safety in patients with non-AF tachyarrhythmias?
Observational (n=52)
No
Does zero-fluoroscopy catheter ablation achieve immediate success and safety in patients with non-AF tachyarrhythmias?
Zero-fluoroscopy catheter ablation using 3D mapping is safe and highly effective for treating various non-AF tachyarrhythmias, eliminating ionizing radiation exposure.
Answers are grounded in this paper and cite their sources.
Supports zero-fluoroscopy ablation feasibility; leaves open need for randomized trials before clinical adoption.
Objective: Catheter ablation (CA) is a highly effective procedure for treating symptomatic tachyarrhythmias. However, the use of fluoroscopy, which is commonly employed in CA, exposes patients and medical personnel to ionizing radiation and its associated health risks. To address this concern, alternative techniques such as electro anatomical mapping and intracardiac ultrasound have emerged as viable options for performing CA without fluoroscopy. This study aims to describe the process and outcomes of mapping and ablation procedures performed without fluoroscopy in a Mexican electrophysiology laboratory. Methods: Fifty-two patients with arrhythmias except atrial fibrillation were included in the study. The threedimensional mapping system ENSITE Precision (Abbott) and intracardiac ultrasound, were used when the operator deemed it necessary. We assessed complications and immediate success of catheter ablation in our patients. Results: A total of 52 patients were included in the study from January 2021 to July 2022of which 24 were men (42%) and 32 were women (57%). Only four patients received diagnostic three-dimensional mapping as a result of clinical tachycardia not being caused. An ablation of 52 arrhythmias substrates was performed with the following results: atrioventricular nodal reentry tachycardia in 20 cases (35.7%), typical atrial flutter in 16 cases (28.57%), atrioventricular re-entrant tachycardia mediated by concealed left accessory pathways in 4 cases (7%), manifest left accessory pathways in 3 cases (5.35%), manifest right accessory pathway in 2 cases (3.57%), right atrium tachycardia in 2 cases (3.8%), left atrium tachycardia in 3 cases (5.35%), right ventricular outflow tract ventricular extrasystoles in 2 cases (3.8%). The average duration of the procedure was 112.46 minutes. The immediate success rate was 100% in all ablated patients. An intracardiac ultrasound was used in 12.5% of cases.
No takes yet. Share an insight, caveat, or question.
Rojel-Martínez et al. (2023) conducted an observational in Cardiac arrhythmias (excluding atrial fibrillation) (n=52). Zero-fluoroscopy catheter ablation (using 3D mapping and intracardiac ultrasound) was evaluated on Immediate success rate of catheter ablation. Zero-fluoroscopy catheter ablation using three-dimensional mapping achieved a 100% immediate success rate with no complications in patients with various tachyarrhythmias.