Key result
Fluoroscopy-free catheter ablation using EAM achieves 81% immediate success with no complications.
Observational (n=11)
No
Catheter ablation of select cardiac arrhythmias can be feasibly and safely performed exclusively using electroanatomic mapping, avoiding the risks of fluoroscopy.
Supports zero-fluoroscopy ablation feasibility in select cases; leaves open broader adoption pending prospective trials.
BACKGROUND: Catheter ablation is a treatment that can cure various cardiac arrhythmias. Fluoroscopy is used to locate and direct catheters to areas that cause arrhythmias. However, fluoroscopy has several risks. Electroanatomic mapping (EAM) facilitates three-dimensional imaging without X-rays, which reduces risks associated with fluoroscopy. OBJECTIVE: We describe a series of patient cases wherein cardiac arrhythmia ablation was exclusively performed using EAM. METHODS: Patients who presented with cardiac arrhythmias that were unresponsive to pharmacological therapy were prospectively selected between March 2011 and March 2012 for arrhythmia ablation exclusively through EAM. Patients with indications for a diagnostic electrophysiology study and ablation of atrial fibrillation, left atrial tachyarrhythmias as well as hemodynamically unstable ventricular arrhythmia were excluded. We documented the procedure time, success rate and complications as well as whether fluoroscopy was necessary during the procedure. RESULTS: In total, 11 patients were enrolled in the study, including seven female patients (63%). The mean age of the patients was 50 years (SD ± 16.5). Indications for the investigated procedures included four cases (35%) of atrial flutter, three cases (27%) of pre-excitation syndrome, two cases (19%) of paroxysmal supraventricular tachycardia and two cases (19%) of ventricular extrasystoles. The mean procedure duration was 86.6 min (SD ± 26 min). Immediate success (at discharge) of the procedure was evident for nine patients (81%). There were no complications during the procedures. CONCLUSION: This study demonstrates the feasibility of performing an arrhythmia ablation exclusively using EAM with satisfactory results.
No takes yet. Share an insight, caveat, or question.
Pires et al. (2013) conducted an observational in Cardiac arrhythmias (n=11). Catheter ablation exclusively using electroanatomic mapping (EAM) was evaluated on Immediate success of the procedure (at discharge). Catheter ablation of cardiac arrhythmias performed exclusively using electroanatomic mapping without fluoroscopy achieved an immediate success rate of 81% with no complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: