Answers are grounded in this paper and cite their sources.
AbstractObjectiveThe primary purpose of this study was to evaluate the effectiveness of a three‐dimensional (3D) software tool (smart planes) for displaying fetal brain planes, and the secondary purpose was to evaluate its accuracy in performing automatic measurements.Material and methodsThis prospective study included singleton fetuses with a gestational age (GA) greater than 18 weeks. Transabdominal two‐dimensional ultrasound (2DUS) and 3D smart planes images were respectively used to obtain the basic planes of the fetal brain, with five parameters measured. The images, by either two‐dimensional (2D) manual or 3D automatic operation, were reviewed by two experienced sonographers. The agreements between two measurements were analyzed.ResultsA total of 226 cases were included. The rates of successful detection by automatic display were as high as 80%. There was substantial agreement between the measurements of the biparietal diameter, head circumference and transcerebellar diameter, but poor agreement between the measurements of cisterna magna and lateral ventricle width.ConclusionsSmart Planes might be valuable for the rapid evaluation of fetal brain, because it simplifies the evaluation process. However, the technology requires improvement. In addition, this technology cannot replace the conventional manual US scans; it can only be used as an additional approach.
No takes yet. Share an insight, caveat, or question.
Meng et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: