Answers are grounded in this paper and cite their sources.
Ferromagnetic resonance measurements were taken on a 4 μm diam disk using a planar microwave transmission line device. The absorption modes of a sample placed on this device can be measured by monitoring the microwave power transmitted across the device while a swept magnetic field varies the sample absorption through resonance. Results for the disk, which was etched from a 105 nm thick amorphous Fe80B15Si5 film, followed the Kittel model over the frequency range from 2 to 20 GHz, in agreement with parameters measured on 5 mm diam disks by a microwave cavity. These results indicate the device has a sensitivity of 3×109⋅ΔH spins, almost two orders of magnitude better than microwave cavity measurements.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: