Answers are grounded in this paper and cite their sources.
Spray contactors capture CO2 with a low pressure drop and no packing, but the temperature of each atomised solvent droplet, which controls how much solvent is lost to evaporation and degradation, has not been used as a design variable. We model a co-current aqueous monoethanolamine (MEA) spray, resolving the two-stage thermal history of a droplet: a brief evaporative-cooling dip as it enters the flue gas, then a temperature bulge as it absorbs CO2. A dimensionless reactive drying number separates this bulge-dominated regime, characteristic of dense post-combustion sprays, from the dip-dominated dilute limit relevant to direct air capture. Managing the thermal state, by placing gentle inter-stage cooling on the rising flank of the bulge, decouples capture from solvent loss. The best place to cool is set by the droplet’s own thermal development rather than by a fixed fraction of the column height (the packed-bed rule). A capture-versus-solvent-loss trade-off and a $/t-CO2 analysis indicate that gentle cooling-water intercooling cuts in-flight amine volatilisation by 18% to 30% across 2m to 8m spray sections at about a one-point capture cost and is roughly cost-neutral, so its value lies in emission control, whereas deep chilling is counterproductive. Multi-stage re-spray additionally lowers the collected-solvent (sump) temperature. The sub-models are validated against published droplet and pilot data; the placement, trade-off and economic results are model predictions awaiting spray-cooling measurements.
No takes yet. Share an insight, caveat, or question.
Sefidan et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: