Answers are grounded in this paper and cite their sources.
On-chip waveguide sensors are potential candidates for deep-space exploration because of their high integration and low power consumption. Since the fundamental absorption of most gas molecules exists in the mid-infrared (e.g., 3–12 μm), it is of great significance to fabricate wideband mid-infrared sensors with high external confinement factor (ECF). To overcome the limited transparency window and strong waveguide dispersion, a chalcogenide suspended nanorib waveguide sensor was proposed for ultra-wideband mid-infrared gas sensing, and three waveguide sensors (WG 1 –WG 3 ) with optimized dimensions exhibit a wide waveband of 3.2–5.6 μm, 5.4–8.2 μm, and 8.1–11.5 μm with exceptionally high ECFs of 107–116%, 107–116%, and 116–128%, respectively. The waveguide sensors were fabricated by a two-step lift-off method without dry etching to reduce the process complexity. Experimental ECFs of 112%, 110%, and 110% were obtained at 3.291 μm, 4.319 μm, and 7.625 μm, respectively, through methane (CH 4 ) and carbon dioxide (CO 2 ) measurements. A limit of detection of 5.9 ppm was achieved for an averaging time of 64.2 s through the Allan deviation analysis of CH 4 at 3.291 μm, leading to a comparable noise equivalent absorption sensitivity of 2.3 × 10 –5 cm –1 Hz –1/2 as compared to the hollow-core fiber and on-chip gas sensors.
No takes yet. Share an insight, caveat, or question.
Pi et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: