Does a single-beat approach accurately estimate ESPDR and PRSW compared to multiple-beat methods in conscious dogs?
Does a single-beat approach accurately estimate ESPDR and PRSW compared to multiple-beat methods in conscious dogs?
Answers are grounded in this paper and cite their sources.
A novel single-beat approach accurately estimates load-insensitive measures of contractility (ESPDR and PRSW) without requiring multiple beats over a wide volume range.
OBJECTIVE: The end-systolic pressure-dimension relationship (ESPDR) and the preload recruitable stroke work (PRSW) relationship are load-insensitive measures of contractility, but their clinical application has been limited by the need to record multiple beats over a wide volume range. In this study, we therefore sought to validate a new method to concomitantly determine the ESPDR and the PRSW relationship from a single beat. METHODS: Pressure-dimension loops were recorded in 14 conscious dogs under various haemodynamic and pathological conditions. Multiple-beat PRSW relationship was determined for its slope (Mw) and for a dimension-axis intercept (Dw). The ESPDR represented by the formula [Formula: see text], was estimated from a steady-state, single-beat late-systolic pressure-dimension relationship. The single-beat Mw was determined as an end-systolic pressure when the end-systolic dimension was equal to Dw. RESULTS: A strong correlation was observed between multiple-beat and single-beat ESPDRs (zero-stress dimension; r=0.98, p<0.0001). The single-beat estimation of Mw calculated using the wall thickness was strongly correlated with the actual Mw (r=0.93, p<0.0001) and was sensitive enough to detect the change in contractility by dobutamine infusion (p<0.001) and by tachycardia-induced heart failure (p<0.001). Similar results were obtained for Mw estimated without information on wall thickness. CONCLUSIONS: Mw can be interpreted as an end-systolic pressure when the end-systolic dimension is equal to Dw. By using the non-linear ESPDR, accurate single-beat estimation of the ESPDR and Mw is possible even without information on wall thickness. These results should enhance the applicability of pressure-volume framework to clinical medicine.
No takes yet. Share an insight, caveat, or question.
Inuzuka et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: