Why the study?
Wearable heart rate variability-based seizure detection devices for focal epileptic seizures show good sensitivity, but false alarm rates remain too high.
Does a patient-adaptive LRML algorithm improve the sensitivity and false alarm rate of HRV-based seizure detection in patients with focal epilepsy?
Does a patient-adaptive LRML algorithm improve the sensitivity and false alarm rate of HRV-based seizure detection in patients with focal epilepsy?
A patient-adaptive logistic regression machine learning algorithm based on HRV significantly reduces false alarm rates for seizure detection compared to previous methods.
Answers are grounded in this paper and cite their sources.
May lower false alarms in focal epilepsy monitoring; leaves open clinical adoption pending prospective validation.
PURPOSE: Wearable automated detection devices of focal epileptic seizures are needed to alert patients and caregivers and to optimize the medical treatment. Heart rate variability (HRV)-based seizure detection devices have presented good detection sensitivity. However, false alarm rates (FAR) are too high. METHODS: In this phase-2 study we pursued to decrease the FAR, by using patient-adaptive logistic regression machine learning (LRML) to improve the performance of a previously published HRV-based seizure detection algorithm. ECG-data were prospectively collected using a dedicated wearable electrocardiogram-device during long-term video-EEG monitoring. Sixty-two patients had 174 seizures during 4,614 h recording. The dataset was divided into training-, cross-validation-, and test-sets (chronological) in order to avoid overfitting. Patients with >50 beats/min change in heart rate during first recorded seizure were selected as responders. We compared 18 LRML-settings to find the optimal algorithm. RESULTS: The patient-adaptive LRML-classifier in combination with using only responders to train the initial decision boundary was superior to both the generic approach and including non-responders to train the LRML-classifier. Using the optimal setting of the LRML in responders in the test dataset yielded a sensitivity of 78.2% and FAR of 0.62/24 h. The FAR was reduced by 31% compared to the previous method, upholding similar sensitivity. CONCLUSION: The novel, patient-adaptive LRML seizure detection algorithm outperformed both the generic approach and the previously published patient-tailored method. The proposed method can be implemented in a wearable online HRV-based seizure detection system alerting patients and caregivers of seizures and improve seizure-count which may help optimizing the patient treatment.
No takes yet. Share an insight, caveat, or question.
Jeppesen et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: