Why the study?
Wearable heart rate variability-based seizure detection devices for focal epileptic seizures show good sensitivity, but false alarm rates remain too high.
Does a patient-adaptive LRML algorithm improve the sensitivity and false alarm rate of HRV-based seizure detection in patients with focal epilepsy?
Does a patient-adaptive LRML algorithm improve the sensitivity and false alarm rate of HRV-based seizure detection in patients with focal epilepsy?
A patient-adaptive logistic regression machine learning algorithm based on HRV significantly reduces false alarm rates for seizure detection compared to previous methods.
May lower false alarms in focal epilepsy monitoring; leaves open clinical adoption pending prospective validation.
PURPOSE: Wearable automated detection devices of focal epileptic seizures are needed to alert patients and caregivers and to optimize the medical treatment. Heart rate variability (HRV)-based seizure detection devices have presented good detection sensitivity. However, false alarm rates (FAR) are too high. METHODS: In this phase-2 study we pursued to decrease the FAR, by using patient-adaptive logistic regression machine learning (LRML) to improve the performance of a previously published HRV-based seizure detection algorithm. ECG-data were prospectively collected using a dedicated wearable electrocardiogram-device during long-term video-EEG monitoring. Sixty-two patients had 174 seizures during 4,614 h recording. The dataset was divided into training-, cross-validation-, and test-sets (chronological) in order to avoid overfitting. Patients with >50 beats/min change in heart rate during first recorded seizure were selected as responders. We compared 18 LRML-settings to find the optimal algorithm. RESULTS: The patient-adaptive LRML-classifier in combination with using only responders to train the initial decision boundary was superior to both the generic approach and including non-responders to train the LRML-classifier. Using the optimal setting of the LRML in responders in the test dataset yielded a sensitivity of 78.2% and FAR of 0.62/24 h. The FAR was reduced by 31% compared to the previous method, upholding similar sensitivity. CONCLUSION: The novel, patient-adaptive LRML seizure detection algorithm outperformed both the generic approach and the previously published patient-tailored method. The proposed method can be implemented in a wearable online HRV-based seizure detection system alerting patients and caregivers of seizures and improve seizure-count which may help optimizing the patient treatment.
No takes yet. Share an insight, caveat, or question.
Jeppesen et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: