A method to analyze the steady-state open loop behaviour of a self-excited induction generator with an unregulated prime mover is presented. The proposed method needs little mathematical effort and does not require an assumption about the generator speed. The proposed approach based on nodal analysis allows one to use arbitrary functions for the torque-speed characteristic of the prime mover and for the saturation of the magnetizing inductance without complicating the solution process. It always leads to a single equation for the frequency. An example is presented demonstrating the advantages of the proposed method. The analytical results are verified by measurements.>
No takes yet. Share an insight, caveat, or question.
Rajakaruna et al. (1993) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: