Answers are grounded in this paper and cite their sources.
The magnetic field distribution in saturable iron parts of electrical machines is defined by a quasi-Poisson equation. The solution to this equation is obtained by minimizing an energy functional by means of trial functions defined in triangular subregions of the two-dimensional field region. This method is applied to an electrical machine for predicting its no-load and on-load performance. Good agreement is obtained between estimated values and test results. Under load conditions, since the pole axis is not an axis of symmetry, a new boundary condition is introduced. Graphical plots of the flux distribution for the machine under different operating conditions are shown.
No takes yet. Share an insight, caveat, or question.
M. Chari (1974) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: