Why the study?
Does stent implantation improve hemodynamics and vessel diameter in patients with pulmonary artery stenosis?
Does stent implantation improve hemodynamics and vessel diameter in patients with pulmonary artery stenosis?
Answers are grounded in this paper and cite their sources.
Stent implantation is effective in immediately reducing the peak systolic gradient and increasing vessel diameter in patients with pulmonary artery stenosis, though significant procedural complications can occur.
Our objective was to assess the immediate and short-term results of stent implantation to relieve pulmonary artery stenosis (PAS). Thirty-seven patients underwent an attempt at stent implantation at a median age of 7.0 years (range, 0.8-31.4 years) and a median weight of 20.5 kg (range, 7.4-85 kg). Twenty-two patients had previous tetralogy of Fallot repair. A total of 55 stents were implanted successfully in 36 patients. The peak systolic gradient across the stenotic segment decreased from a mean of 43 +/- 20.4 mmHg prestent to 13 +/- 13.9 mmHg (P < 0.001) poststent. The diameter of the narrowest segment increased from a mean of 4.8 +/- 1.6 mm to 10.5 +/- 2.6 mm (P < 0.001). The right ventricular-to-aortic mean systolic pressure ratio decreased from 0.74 +/- 0.2 to 0.52 +/- 0.19 (P < 0.001). Complications included balloon rupture prior to full stent expansion in 4 patients (in 2 patients the stent was positioned in the superior vena cava, and in 2 in the inferior vena cava), distal migration of a stent which was successfully retrieved at surgery 1 mo later in 1 patient, and tethering of the stent to the balloon requiring surgical removal in 1 patient. One patient died several hours after stent placement. Sixteen patients underwent repeat catheterization at a mean follow-up interval of 0.9 +/- 0.5 years (range, 0.2-2.0 years). The mean gradient across the stent for these 16 patients was 26.7 +/- 19.8 mmHg, and there was no change in the mean diameter (9.4 +/- 3.2 mm). Two patients developed stenosis related to neointimal proliferation at the stent site which was redilated successfully. In conclusion, stent implantation is generally safe and effective in relieving PAS.
No takes yet. Share an insight, caveat, or question.
Hijazi et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: