Key result
Unsupervised autoencoder-based model achieves ~90% accuracy in classifying fetal ECG signal quality.
Why the study?
Accurate fetal heart rate estimation from non-invasive fetal ECG is hindered by noise, and existing supervised signal quality assessment methods require large annotated datasets, which are limited.
Does an unsupervised learning-based multi-level signal quality assessment using autoencoder features and a self-organizing map accurately classify non-invasive fetal ECG signal quality and reduce fetal heart rate estimation error in healthy pregnant subjects?
Does an unsupervised learning-based multi-level signal quality assessment using autoencoder features and a self-organizing map accurately classify non-invasive fetal ECG signal quality and reduce fetal heart rate estimation error in healthy pregnant subjects?
This unsupervised self-organizing map and spectrogram autoencoder approach classifies non-invasive fetal ECG quality into three levels with a 90% F1-score without requiring large annotated training datasets, reducing fetal heart rate estimation errors when low-quality segments are removed.
Answers are grounded in this paper and cite their sources.
May aid automated fetal ECG quality control without annotations; leaves open prospective validation before clinical adoption.
OBJECTIVE: To monitor fetal health and growth, fetal heart rate is a critical indicator. The non-invasive fetal electrocardiogram is a widely employed measurement for fetal heart rate estimation, which is extracted from the electrodes placed on the surface of the maternal abdomen. The qualities of the fetal ECG recordings, however, are frequently affected by the noises from various interference sources. In general, the fetal heart rate estimates are unreliable when low-quality fetal ECG signals are used for fetal heart rate estimation, which makes accurate fetal heart rate estimation a challenging task. So, the signal quality assessment for the fetal ECG records is an essential step before fetal heart rate estimation. In other words, some low-quality fetal ECG signal segments are supposed to be detected and removed by utilizing signal quality assessment, so as to improve the accuracy of fetal heart rate estimation. A few supervised learning-based fetal ECG signal quality assessment approaches have been introduced and shown to accurately classify high- and low-quality fetal ECG signal segments, but large fetal ECG datasets with quality annotation are required in these methods. Yet, the labeled fetal ECG datasets are limited. Proposed methods: An unsupervised learning-based multi-level fetal ECG signal quality assessment approach is proposed in this paper for identifying three levels of fetal ECG signal quality. We extracted some features associated with signal quality, including entropy-based features, statistical features, and ECG signal quality indices. Additionally, an autoencoder-based feature is calculated, which is related to the reconstruction error of the spectrograms generated from fetal ECG signal segments. The high-, medium-, and low-quality fetal ECG signal segments are classified by inputting these features into a self-organizing map. MAIN RESULTS: The experimental results showed that our proposal achieved a weighted average F1-score of 90% in three-level fetal ECG signal quality classification. Moreover, with the acceptable removal of detected low-quality signal segments, the errors of fetal heart rate estimation were reduced to a certain extent.
No takes yet. Share an insight, caveat, or question.
Shi et al. (2023) studied Healthy pregnancy undergoing non-invasive fetal ECG monitoring (n=10). Unsupervised learning-based multi-level fetal ECG signal quality assessment using autoencoder-derived spectrogram features, multi-class feature selection, and self-organizing map (SOM) classification vs. Benchmark unsupervised clustering methods (K-means, K-means++, hierarchical clustering, spectral clustering) and fetal heart rate estimation without removal of low-quality segments was evaluated on Weighted average F1-score in three-level (high, medium, and low) fetal ECG signal quality classification. Unsupervised self-organizing map classification using autoencoder and signal quality features achieved a 90% weighted average F1-score for three-level fetal ECG signal quality assessment.
Synapse has enriched 10 related papers. Consider them for comparative context: