Why the study?
Does a multilinear regression model based on Doppler variables (E and PV) accurately estimate pulmonary capillary wedge pressure in patients with various cardiac disease states?
Does a multilinear regression model based on Doppler variables (E and PV) accurately estimate pulmonary capillary wedge pressure in patients with various cardiac disease states?
Answers are grounded in this paper and cite their sources.
A multilinear regression model using Doppler variables E and PV provides a noninvasive method to accurately estimate pulmonary capillary wedge pressure across different cardiac conditions.
The present study was performed to determine whether a multilineal regression model based on the early diastolic transmitral flow peak velocity (E) and the propagation velocity of early diastolic inflow (PV) could estimate the pulmonary capillary wedge pressure (PCWP). PCWP and Doppler variables were simultaneously recorded in 30 patients. PCWP was estimated by multilinear regression analysis using E and PV. The predictive accuracy of the equation obtained from the analysis was tested prospectively in a separate group of 65 patients divided into 3 groups: left ventricular (LV) systolic dysfunction (Group A), LV hypertrophy (Group B), and preserved systolic function without hypertrophy (Group C). The initial results obtained in groups B and C, respectively, were: r=0.77; r=0.81. These results indicate that a multilinear regression model based on E and PV is a noninvasive method of accurately estimating PCWP in a variety of cardiac disease states.
No takes yet. Share an insight, caveat, or question.
Seo et al. (2001) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: