Key result
ICE-guided LAAO succeeds safely despite a pre-existing 34 mm atrial septal occluder.
Why the study?
Patients with prior atrial septal defect closure present a significant challenge for transseptal access during left atrial appendage occlusion.
Is intracardiac echocardiography-guided left atrial appendage occlusion from the left atrium feasible and safe in a patient with a large 34 mm atrial septal defect occluder?
Case Report (n=1)
No
Is intracardiac echocardiography-guided left atrial appendage occlusion from the left atrium feasible and safe in a patient with a large 34 mm atrial septal defect occluder?
Prior atrial septal defect closure with a large 34 mm occluder is not an absolute contraindication to left atrial ICE-guided LAAO when supported by preprocedural cardiac CT planning.
Answers are grounded in this paper and cite their sources.
May support ICE-guided LAAO feasibility after large ASD occluder; leaves open safety and efficacy in broader populations.
Background: Intracardiac echocardiography (ICE)-guided left atrial appendage occlusion (LAAO) is increasingly common. Patients with previous atrial septal defect closure constitute a significant challenge for transseptal access. Case summary: A 49-year-old man with persistent atrial fibrillation, hypertension, and reduced left ventricular function was considered for LAAO after a life-threatening intrathoracic bleeding while on oral anticoagulation. Percutaneous atrial septal defect closure was performed 15 years before with a 34 mm Amplatzer Septal Occluder. Preprocedural cardiac computed tomography demonstrated the atrial septal occluder device with a small native interatrial septum at the inferior margin. The left atrial appendage landing zone measured 17 × 22 mm. The LAAO was performed under local analgesia. A steerable sheath was used to guide the transseptal puncture, and the ICE probe was traced along a guidewire across the atrial septum. A 12-F Amulet delivery sheath was advanced through the same transseptal hole. Under ICE and fluoroscopy guidance, a 25 mm Amplatzer Amulet was deployed. Follow-up imaging showed a well-positioned device with a small peridevice leak at the disc. Discussion: This case report illustrates the feasibility of LAAO performed with ICE guidance from the left atrium in a patient with a large Amplatzer Septal Occluder with a small native interatrial septum. It demonstrates that prior atrial septal defect closure should not be considered as a contraindication for LAAO but warrants careful preprocedural planning.
No takes yet. Share an insight, caveat, or question.
Korsholm et al. (2023) conducted a case report in Persistent atrial fibrillation with prior atrial septal defect closure (34 mm Amplatzer Septal Occluder) and life-threatening bleeding on oral anticoagulation (n=1). Intracardiac echocardiography-guided left atrial appendage occlusion with a 25 mm Amplatzer Amulet was evaluated on Successful device deployment and absence of periprocedural complications or clinical events at 2-month follow-up. Intracardiac echocardiography-guided left atrial appendage occlusion with a 25 mm Amplatzer Amulet was successfully performed in 57 minutes without complications despite a 34 mm atrial septal occluder.
Synapse has enriched 10 related papers. Consider them for comparative context: