Key result
Catheter ablation of atrial fibrillation in patients with an atrial septal occluder was feasible and safe, maintaining sinus rhythm in 75% (12 of 16) of patients over 16 months.
Why the study?
Is catheter ablation of atrial fibrillation feasible and safe in patients with a previously implanted atrial septal occluder?
Observational (n=16)
No
Is catheter ablation of atrial fibrillation feasible and safe in patients with a previously implanted atrial septal occluder?
Catheter ablation of atrial fibrillation is feasible and safe in patients with an atrial septal occluder, and balloon dilatation can successfully facilitate transseptal access when native septum passage is not possible.
Answers are grounded in this paper and cite their sources.
Suggests transseptal access and ablation may be technically feasible despite septal oc.
Aims: Catheter ablation is underutilized in atrial septal defect (ASD) patients who have undergone implantation of an atrial septal occluder (ASO). This study evaluates the feasibility and safety of catheter ablation of atrial fibrillation (AF) in this subset of patients. Methods and results: Sixteen patients (age 56 ± 12 years, 10 men) with drug-refractory AF (10 paroxysmal and 6 persistent) and previously implanted ASO were enrolled. Balloon dilatation of the closure device was performed if the native septum passage could not be achieved. For paroxysmal AF, the ablation strategy was circumferential pulmonary vein isolation (CPVI), and for persistent AF, additional linear ablation was performed. Transseptal access was achieved through the native septum in 11 patients (Group A) and through the ASO using balloon dilatation in 5 patients (Group B). Circumferential pulmonary vein isolation was achieved in all 16 patients, and linear block was achieved in all persistent patients except for 1 patient who did not achieve mitral isthmus block. The transseptal, total fluoroscopy, and procedural durations were 5 ± 3 vs. 38 ± 8 min, 31 ± 11 vs. 54 ± 15 min, and 165 ± 35 vs. 224 ± 36 min, respectively, in Group A vs. Group B, respectively (all P < 0.05). No shunt at atrial level was detected by transthoracic echocardiography at 3-month follow-up. During a follow-up of 16 ± 6 months, sinus rhythm was maintained in 12 of 16 patients. No severe complications were observed. Conclusion: In ASD patients with ASO, catheter ablation of AF is feasible, safe, and effective. The balloon dilatation technique can facilitate transseptal access through the ASO.
No takes yet. Share an insight, caveat, or question.
Sang et al. (2017) conducted an observational in Atrial fibrillation in patients with atrial septal occluder (n=16). Catheter ablation of atrial fibrillation was evaluated on Maintenance of sinus rhythm. Catheter ablation of atrial fibrillation in patients with an atrial septal occluder was feasible and safe, maintaining sinus rhythm in 75% (12 of 16) of patients over 16 months.
Synapse has enriched 10 related papers. Consider them for comparative context: